wireless data solutions
RMU2-G: Full Features List
- Simple and very quick to install (typically under 1 hour)
- High reliability, long operational life design
- Low capital equipment cost
- Economical fixed rate operational communication costs
- Quad band GSM cellular operation (850/900/1800/1900MHz)
- Four galvanically isolated analog input channels
- Each analog channel is bi-polar and installer configurable
150mV (50 and 100mV current shunts), 20V, 165V, and 4-20mA
measurement ranges
- Each analog channel can be configured to read DC or True RMS
AC (i.e. induced AC measurements)
- DC analog channels include >65dB of 50/60Hz AC rejection
- All analog channels are high impedance and allow direct
connection to reference half-cells
- All analog channels are factory calibrated for simple
"connect and go" operation
- Analog channel measurement accuracy of ±0.5% DC and ±1% AC FS
over -40 to +70°C (-40 to +158°F)
- Programmable low and high alarm window capability on each
analog channel with report by exception facilities
- Scheduled reporting of data based on customer selected plan
(every 6 hours, daily, every 2 days, or weekly readings)
- Each channel has independent very high voltage lightning
protection (will survive 20kV 10ms surge)
- No connection to ground for maximum lightning immunity
- Internal temperature measurement and reporting
- Powered exclusively from an internal battery for maximum
lightning isolation and simplicity
- Primary battery will last for more than six years based on
readings every 2 days with a transmission every 8 days
- Primary battery is integral to the device but is user replaceable
and readily available
- Compact two piece mechanical design
- Termination block assembly is 100mm x 38mm x 38mm (4.0" x 1.5"
x 1.5") and environmentally sealed (mounts in rectifier)
- GSM cellular transmitter assembly is 97mm x 97mm x 132mm
(3.8" x 3.8" x 5.2") and mounts externally
- Components connect together wit a single polyurethane cable
with small (0.5" diameter) molded waterproof connectors
- Transmitter includes a bottom side ½" threaded receptacle that
mates directly to electrical conduit fittings
- Easy configuration through a USB PC interface
- Rectifier GPS position information transmitted to
corView host
- IP67 sealed enclosure and cabling for harsh environments
- Operation in -40°C to +70°C (-40 to 158°F) temperatures
- Integral AC line voltage inductive coupling sensor for safe
and lightning immune detection of primary line voltage
- Magnetic door switch / tamper sensor with exception report